Flo-Motion™

TECHNICAL SPECIFICATIONS

Flo-Motion Selection Process


1. Choose available air supply pressure to be used (up to 425 kPa)

2. Determine total weight (load) of object to be moved (kgs)

3. Determine minimum quantity of FLO-MOTION units under load:

Qty FLO-MOTION=(Load/Air Pressure)/ 0.0264

Example:
Load = 50 kgs
Available Air Supply Pressure = 425 kPa

Qty of FLO-MOTION = (50 kg / 425 kPai) / 0.0264 = 5 FLO-MOTION units under load at 425 kPa

This will determine the minimum number of FLO-MOTION units required to support the load. We recommend that this number be at least 9 to allow for the movement on a pattern. If the calculated quantity is less than 9, more FLO-MOTION units using less air pressure will be required.

Example:
In the example above, only 5 FLO-MOTION’s are required. Therefore, more FLO-MOTION units using less air pressure are required. Calculate the required pressure based on 9 FLO-MOTION units.

Air Pressure = (50 kg / 9) / 0.0264 = 210 kPa, use 210 kPa.
Qty. of FLO-MOTION = (50 kPa / 210 kPa) / 0.0264 = 9 FLO-MOTION at 210 kPa psi

Alternately, the allowable load per FLO-MOTION can be determined from the chart below.

Total Allowable load in Pounds
Quantity of FLO-Motion Units
9 10 11 12 13 14 15 16 17 18 19 20
Allowable load per Flo-Motion (lbs.)
Air Pressure (psi)
                       
2.0
75
18
20
22
24
26
28
30
32
34
36
38
40
2.6
100
23 26 29 31 34 36 39 42 44 47 49 52
3.3
125
30 33 36 40 43 46 50 53 56 59 63 66
4.0
150
36 40 44 48 52 56 60 64 68 72 76 80
5.3
200
48 53 58 64 69 74 80 85 90 95 101 106
5.9
225
53 59 65 71 77 83 89 94 100 106 112 118
6.6
250
59 66 73 79 86 92 99 106 112 119 125 132
7.2
275
65 72 79 86 94 101 108 115 122 130 137 144
7.9
300
71 79 87 95 103 111 119 126 134 142 150 158
8.6
325
77 86 95 103 112 120 129 138 146 155 163 172
9.2
350
83 92 101 110 120 129 138 147 156 166 175 184
9.9
375
89 99 109 119 129 139 149 158 168 179 188 198
10.5
400
95 105 116 126 137 147 158 168 179 189 200 210
11.2
425
101 112 123 134 146 157 168 179 190 202 213 224